Sign In | Join Free | My himfr.com
Home > Earth Fault Indicator >

Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy

    Buy cheap Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy from wholesalers
     
    Buy cheap Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy from wholesalers
    • Buy cheap Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy from wholesalers
    • Buy cheap Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy from wholesalers

    Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy

    Ask Lasest Price
    Brand Name : Tianyihongda
    Model Number : TYHD-R0
    Certification : type test report
    Price : Negotiation
    Payment Terms : Western Union, L/C, T/T
    Supply Ability : 3000sets per week
    Delivery Time : 3000 sets within 1 week
    • Product Details
    • Company Profile

    Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy

    This kind of device is applied to the overhead power distribution network automatic system from 6KV to 35KV,is used to improve the safe and reliable operating performance through centralized monitoring the current, temperature and fault condition on the power distribution circuit.

    system Constructure:

    Main features:

    GSM or GPRS forwarding;

    GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.

    Remote upgrade;

    The equipment program can be upgraded conveniently through master remote maintenance station.

    Work mode setting;

    The terminal can be in the two-remote or one-remote working mode by setting the intrinsic parameters of remote terminal uint.

    Two-remote working mode: the terminal is online in real time, and the circuit load current and circuit status can be uploaded.

    One-remote working mode: the terminal is online regularly; when the circuit breaks down, the terminal opens GPRS module power supply and sends the fault information to main distribution network station.

    Functions:

    1)Wireless receiving: the fault point information and load current information sent by indicator are received via short-range wireless network mode.

    2)GSM or GPRS forwarding: GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.

    3)Solar power supply: the solar power supply mode is applied, and the maintenance-free 8AH lead-acid battery or 12AH lithium iron phosphate battery is provided, with the working temperature range of both batteries of -35℃~75 ℃ and -20℃~75℃ separately.

    4)Optional communication protocol: IEC870-5-101 protocol or 104 can be selected for the connection with the third party equipment to upload the fault and shift information.

    5)Remote upgrade: the equipment program can be upgraded conveniently through master remote maintenance station.

    6)Convenient maintenance: the parameter setting and equipment maintenance can be performed conveniently via wireless setting terminal.

    7)Event recording: the device can record the maximum 500 pieces of SOE events, providing the rich data support for system fault analysis.

    Definition of Terminal:

    There is type test report for it, test items as following:


    Type Test Items


    1. appearance and structure 2.function 3. electrical device performance 4.low temperature performance 5.high temperature performance 6.alternating temperature humidity7.vibrationendurance 8.incline drop test 9. electrical device life 10. static electricity and elecro-discharge immunity test 11.radio frequency electromagnetic field radiated immunity test 12.surge impact immunity test 13. power frequency magnetic field immunity test. 14. Adjacent interference test 15.short-circuit withstand impact test 16. fire hazard test 17. power consumption test 18. protection grade test 19. gripping strength test of grip structure.
    Product Tags:

    earth leakage indicator

      

    fault locator

      
    Quality Power Distribution Network Earth Fault Indicator Over 90 / 100 Alarming Accuracy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Tianyihongda Science & Technology Development Co., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)